Home: Marine Catalog: Electronics: Relays:
Dual Operation 275 Amp Voltage Sensitive Relay (VSR) Cat. No. BEP-701-MDVS Weight 2 lbs | $214.06 |
Range Highlights
- Remote emergency parallel function:
the 701-MDVS can be
operated through a momentary button
on the dash which will parallel the
batteries for a preset time of 10 minutes.
Once this 10 minutes has passed, if the
voltage is up high enough for the voltage
sensitive switch to operate, it will stay
engaged. If not, it will disengage.
- Engine run sensing: VSR will engage
when the voltage on either start or
house battery reaches 13.7 volts. If the
combined battery voltage drops below
13.0 volts and the engine is not running,
after 5 seconds the contacts will open
and stay open until the start or house
battery voltage exceeds 13.7 volts. If the
combined battery voltage drops below
12.2 volts and the engine is running, after
5 minutes the contacts will open and stay
open until the start or house battery
voltage exceeds 13.7 volts. If voltage
drops below 13 volts and stays above 12.2
volts on either start or house battery
while engine is running, the VSR will stay
engaged.
- The advantages of using a high current
VSR is that it will cover your dual battery
charging requirements and emergency
parallel operation in one unit.
- Also available in
Emergency parallel only
(no voltage sensitive
function). See table.
High Current Remote operated VSR
|
Part No.
|
mm
L x W x H
|
L x W x H
|
701-MDVS
|
68 x 68 x 101
|
2.7 x 2.7 x 4
|
701-MDVS-24V
|
68 x 68 x 101
|
2.7 x 2.7 x 4
|
High Current Remote operated VSR Specifications
|
Part No.
|
Volts (V)
|
Rating (Amps)
|
Engages
|
Disengages
|
701-MDVS
|
12
|
275
|
13.7
|
12.2 - 13.00
|
701-MDVS-24V
|
24
|
275
|
27.4
|
24.4 - 26.0 |
|
|
|